ba75685e01 01/2007pH/ION 3400iOperating manual8422996°CTPpHARRCLSTOCALMOpH/Ion meter

Strany 2 - © Weilheim 2007, WTW GmbH

Overview pH/ION 3400i101.6 Operating structureThe following overview diagram shows which keys you have to press to select between the different measur

Strany 3

pH/ 3400i Safety112 SafetyThis operating manual contains basic instructions that you must follow during the commissioning, operation and maintenance o

Strany 4 - Contents pH/ION 3400i

Safety pH/ 3400i122.2 General safety instructionsThis instrument is built and inspected according to the relevant guide-lines and norms for electronic

Strany 5 - 1Overview

pH/ 3400i Commissioning133 Commissioning3.1 Scope of deliveryz 3400i handheld meter z Plug-in power supply (optional)z Operating manual and short oper

Strany 6 - 1.2 SETs of equipment

Commissioning pH/ 3400i14Connecting the originalplug-in power supplyunitYou can either operate the measuring instrument with batteries or with the plu

Strany 7

pH/ 3400i Operation154 Operation4.1 Switching on the measuring instrumentNote The measuring instrument has an energy saving feature to avoid un-necess

Strany 8 - 1.3 Keypad

Operation pH/ 3400i164.2 pH value / ORP voltage4.2.1 General informationPreparatory activities Perform the following preparatory activities when you w

Strany 9 - 4 pH temperature sensor

pH/ 3400i Operation174.2.2 Measuring the pH valueSetting the resolutionAutoRead AR(drift control)The AutoRead function (drift control) checks the stab

Strany 10 - 1.6 Operating structure

Operation pH/ 3400i18NoteThe current AutoRead measurement can be terminated at any time (accepting the current value) by pressing <RUN/ENTER>.3

Strany 11 - ECHNICAL DATA

pH/ 3400i Operation194.2.3 Measuring the ORP voltageIn conjunction with an ORP electrode, e.g. SenTix ORP, the measuring instrument can measure the OR

Strany 12 - HAT TO DO IF

Accuracy whengoing to pressThe use of advanced technology and the high quality standard of our instruments are the result of continuous development. T

Strany 13 - EQUIPMENT and WTW catalog

Operation pH/ 3400i204.3 pH calibrationWhy calibrate? pH electrodes age. This changes the asymmetry (zero point) and slope of the pH electrode. As a r

Strany 14 - Commissioning pH/ 3400i

pH/ 3400i Operation21NoteYou can automatically print a calibration protocol after the calibration. To do so, connect a printer to the interface accord

Strany 15 - 4 Operation

Operation pH/ 3400i22Preparatory activities4.3.1 AutoCal TECFor this procedure, use any two WTW technical buffer solutions (pH values at 25 °C: 2.00 /

Strany 16 - 4.2 pH value / ORP voltage

pH/ 3400i Operation23NoteAt this point, the AutoCal TEC calibration can be terminated with <M>. This corresponds to a single-point calibration.

Strany 17 - AutoCal TEC

Operation pH/ 3400i24strument uses the Nernst slope (-59,16 mV/pH at 25 °C) and deter-mines the asymmetry of the electrode.6 Thoroughly rinse the elec

Strany 18 - Operation pH/ 3400i

pH/ 3400i Operation2512 Switch to the measuring mode with <M>.ysamV/pH59TP°CConCalARAutoCal DIN6mol/L8AutoStoreRCLLoBatCalErrorARngTimeBaudDay.

Strany 19

Operation pH/ 3400i264.3.2 AutoCal DINFor this procedure, use two different standard buffer solutions accord-ing to DIN 19266 (type A, C, D or F with

Strany 20 - 4.3 pH calibration

pH/ 3400i Operation27NoteAt this point, the AutoCal DIN calibration can be terminated with <M>. This corresponds to a single-point calibration.

Strany 21

Operation pH/ 3400i2810 When the measured value is stable, AR disappears. The value of the slope (mV/pH) appears on the display. The probe symbol show

Strany 22

pH/ 3400i Operation294.3.3 ConCalTwo-point calibration For this procedure, use two buffer solutions:z pH 7.0 ± 0.5z any other buffer solutionNoteSkip

Strany 23

pH/ION 3400i Contents31 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.1 General features . . . . . . . . .

Strany 24

Operation pH/ 3400i308 Thoroughly rinse the electrode with deionized water.9 If required, enter the temperature of the second buffer solution with <

Strany 25

pH/ 3400i Operation3115 Switch to the measuring mode with <M>.AutoCal DINAutoCal TECysamV/pH59TP°CAR6mol/L8AutoStoreRCLLoBatCalErrorARngTimeBau

Strany 26

Operation pH/ 3400i324.4 Ion concentration4.4.1 General informationPreparatory activities Perform the following preparatory activities when you want t

Strany 27

pH/ 3400i Operation33The temperature measurement is absolutely essential for a reproduc-ible ISE measurement. If the measurement is made without a tem

Strany 28

Operation pH/ 3400i34NoteThe current AutoRead measurement can be terminated at any time (accepting the current value) by pressing <RUN/ENTER>.4.

Strany 29

pH/ 3400i Operation35TP display If you use a temperature sensor, a flashing TP display indicates that the difference in temperature of the standard so

Strany 30

Operation pH/ 3400i36Preparatory activities Perform the following preparatory activities:NoteFor calibration, use tempered standard solutions with a t

Strany 31

pH/ 3400i Operation37Two-point calibration1 Press the <CAL> key. The previously set up concentration of the first standard solution and ConCal a

Strany 32 - ACK FIELD on page 9

Operation pH/ 3400i386 Enter the current concentration of the second standard solution with <▲> <▼>.7 Thoroughly rinse the ion selective e

Strany 33

pH/ 3400i Operation39Three-pointcalibration11 To return to the measuring mode: Press the <M> key or go on to the three-point calibration by pres

Strany 34

Contents pH/ION 3400i45.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645.3 Disposal . . . . . . . . . . . .

Strany 35 - HAT OT DO IF

Operation pH/ 3400i40NoteYou can prematurely terminate the three-point calibration by pressing <M>. The values of the two-point calibration will

Strany 36

pH/ 3400i Operation414.5 Calibration interval (Int 3)The flashing probe symbol reminds you to calibrate regularly (pH/ORP). When the fixed calibratio

Strany 37

Operation pH/ 3400i424.6 SavingThe measuring instrument has an internal data memory. It can store up to 500 data records. A complete data record consi

Strany 38

pH/ 3400i Operation43Message StoFullStoFullStoFullStoFull This message appears when all of the 500 storage locations are occu-pied.You have the follow

Strany 39

Operation pH/ 3400i444.6.2 Switching on AutoStore (Int 1)The save interval (Int 1) determines the chronological interval between automatic save proces

Strany 40

pH/ 3400i Operation45As soon as all of the 500 storage locations are occupied, AutoStore is terminated (Int 1 = OFF). If there are not enough storage

Strany 41

Operation pH/ 3400i464.6.3 Outputting the data storageYou can output the contents of the data storage:z Stored data on the displayz Calibration data o

Strany 42 - 4.6 Saving

pH/ 3400i Operation47NoteIf you want to search for a certain element of the data record (e.g. date), proceed as follows:Outputting stored datato the i

Strany 43 - StoFullStoFull

Operation pH/ 3400i48Sample printout:Outputting thecalibration dataon the display No. 1: 09.03.99 17:10pH 10.013 25 °CTman A

Strany 44

pH/ 3400i Operation493 Press <RUN/ENTER> to display the value of the asymmetry (mV).4 Press <RUN/ENTER> to display the slope of the ion se

Strany 45

pH/ION 3400i Overview51Overview1.1 General featuresThis compact precision handheld meter enables you to carry out pH / ORP measurements and concentrat

Strany 46

Operation pH/ 3400i506 With <M> you can switch back to the last active measuring mode.Day.MonthU°CCalErrorARngTempErrorAR°F%TP11/pHmg/LpHIdentYe

Strany 47 - AutoCal DIN

pH/ 3400i Operation51Outputting the calibra-tion protocol on theinterfaceSample printout:1 Press the <RCL> key repeatedly until CAL SEr appears

Strany 48

Operation pH/ 3400i524.6.4 Clearing the memoryWith this function, you can delete stored data records. 500 storage lo-cations will then be available ag

Strany 49 - CalError

pH/ 3400i Operation534.7 Transmitting data You have the following possibilities of transmitting data:z One of the following options:– With the AutoSto

Strany 50

Operation pH/ 3400i54NoteWhen the AutoStore function is active at the same time, the data trans-mission is performed according to the setting of the s

Strany 51

pH/ 3400i Operation554.7.3 Remote control The measuring instrument can be remotely controlled from a PC. This requires the KOM pilot communication kit

Strany 52

Operation pH/ 3400i564.8 ConfigurationYou can adapt the measuring instrument to your individual require-ments. To do this, the following parameters ca

Strany 53 - 4.7 Transmitting data

pH/ 3400i Operation57CalibrationintervalsDate and time6 Select the required display during the pH calibration with <▲> <▼>.mV: Display of

Strany 54

Operation pH/ 3400i5813 Confirm with <RUN/ENTER>.The year appears on the display.14 Set the current year with <▲> <▼>.15 Confirm wit

Strany 55

pH/ 3400i Operation594.9 Reset You can reset (initialize) the measurement parameters and the config-uration parameters separately from one another.Mea

Strany 56 - 4.8 Configuration

Overview pH/ION 3400i61.2 SETs of equipmentThe measuring instrument is also available as part of individual SETs of equipment. You will find additiona

Strany 57

Operation pH/ 3400i60Resetting themeasuring parameters1 Press the <RUN/ENTER> key and hold it down.2 Press the <CAL> key. The setting to r

Strany 58

pH/ 3400i Operation61Resetting theconfiguration parame-ters5 Using <▲> <▼>, toggle between no and YES.YES: Resetting the configuration par

Strany 59 - 4.9 Reset

Operation pH/ 3400i62

Strany 60

pH/ 3400i Maintenance, cleaning, disposal635 Maintenance, cleaning, disposal5.1 MaintenanceThe measuring instrument is almost maintenance-free. The on

Strany 61

Maintenance, cleaning, disposal pH/ 3400i64NoteFor maintenance of electrodes and ion-selective electrodes, follow the corresponding operating manual.5

Strany 62

pH/ 3400i What to do if...656 What to do if...6.1 pH system messagesError message 0FL0FL0FL0FL Error message E3E3E3E3 Cause RemedypH electrode:– Not

Strany 63 - 5.1 Maintenance

What to do if... pH/ 3400i66 No stable measuredvalue Obviously incorrectmeasured valuesBuffer solutions– Incorrect buffer solutions – Change calibra

Strany 64 - 5.3 Disposal

pH/ 3400i What to do if...676.2 ISE system messagesError message 0FL0FL0FL0FL Error message E3E3E3E3 Concentrationdisplay flashesCause RemedyIon-sele

Strany 65 - 6 What to do if

What to do if... pH/ 3400i68TP and Temp Error flashCalibration Std 2 flashesCalibration Std 3 flashes6.3 General errorsDisplay LoBat Instrument does

Strany 66 - What to do if... pH/ 3400i

pH/ 3400i What to do if...69Display totototo Probe symbol flashes Message Sto Ful lStoFullStoFullStoFull Cause Remedy– Time-out of the interface – Che

Strany 67 - U3 U2– 5mV≤

pH/ION 3400i Overview7Set (sample configuration):1 pH/ION 3400i measuring instrument 2 Stand3 Measuring beaker,50 ml 4 50 ml pH buffer solution, STP 4

Strany 68 - AINTENANCE)

What to do if... pH/ 3400i70

Strany 69

pH/ 3400i Technical data717 Technical dataDimensions and weight Mechanical structureElectrical safetyAmbient conditions pH/ORP measuringranges Preci

Strany 70

Technical data pH/ 3400i72pH temperature input:ISE measuring rangesUsableISE electrodesCombination and double electrodes with connector according to D

Strany 71 - 7 Technical data

pH/ 3400i Technical data73SerialinterfaceAutomatic switchover when a PC or a printer is connected via the cable, AK 340/B or AK 325/S.Power supply Ty

Strany 72 - Technical data pH/ 3400i

Technical data pH/ 3400i74Guidelinesand norms used Test certificates EMC E.C. guideline 89/336/EECEN 61326-1:1997EN 61000-3-2 A14:2000EN 61000-3-3:199

Strany 73

pH/ 3400i Lists758ListsThis chapter provides additional information and orientation aids.Abbreviations The list of abbreviations explains the indicato

Strany 74

Lists pH/ 3400i76AbbreviationsAR AutoRead (drift control)ARng Automatic range switchingMeasuring instrument measures with highest reso-lutionASY Asymm

Strany 75

pH/ 3400i Lists77S Slope (internat. k)SELV Safety Extra Low VoltageSLO Slope setting on calibrationTP Temperature measurement active (Temperature Prob

Strany 76

Lists pH/ 3400i78GlossaryAdjusting To manipulate a measuring system so that the relevant value (e. g. the displayed value) differs as little as possib

Strany 77

pH/ 3400i Lists79Offset potential The measurable potential of a symmetrical electrode, the membrane of which is immersed in a solution with the pH of

Strany 78 - Lists pH/ 3400i

Overview pH/ION 3400i81.3 KeypadKey functionsRUN/ENTERARRCLCALSTOMSelect the measured variable <M>:– pH value / ORP voltage– Ion concentrationSa

Strany 79

Lists pH/ 3400i80

Strany 80

pH/ION 3400i Index81AAsymmetry 20Auslieferzustand 59Authorized use 11AutoCal DIN 20, 26AutoCal TEC 20, 22AutoRead 17ISE measurement 33CCalibration eva

Strany 81

Index pH/ION 3400i82

Strany 82 - Index pH/ION 3400i

Wissenschaftlich-Technische Werkstätten GmbHDr.-Karl-Slevogt-Straße 1D-82362 WeilheimGermanyTel: +49 (0) 881 183-0+49 (0) 881 183-100Fax: +49 (0) 881

Strany 83

pH/ION 3400i Overview91.4 Display1.5 Jack field1 pH electrode or ISE (combination) electrode2 Reference electrode3 Plug-in power supply (optional)4 pH